Techrider.live

Free · No login required

Sabine reverberation estimate

Estimate a room’s 60 dB decay time from volume and equivalent absorption area.

Room volume (m³): 1–1000000; Equivalent absorption area (m² sabin): 0.1–1000000

Inputs stay on this page and clear on refresh.

Sabine reverberation estimate

Room volume (m³): 1000 Equivalent absorption area (m² sabin): 200

Estimated RT60 (s)
0.805000

RT60 = 0.161 V/A, using cubic metres and equivalent absorption area in square metres for one frequency band and occupancy condition. A is the sum of surface area × absorption coefficient plus equivalent object absorption, not floor area or absorber panel area. This simplified Sabine model assumes a diffuse field with fairly uniform, low average absorption; it excludes air absorption. Small rooms, strong modes, highly absorptive or coupled spaces can depart substantially. No target, treatment prescription or measured RT60 is supplied. Record the frequency band and occupancy with your export; measure the actual room.

Methodology

How it works

RT60 = 0.161 V/A, using cubic metres and equivalent absorption area in square metres for one frequency band and occupancy condition. A is the sum of surface area × absorption coefficient plus equivalent object absorption, not floor area or absorber panel area. This simplified Sabine model assumes a diffuse field with fairly uniform, low average absorption; it excludes air absorption. Small rooms, strong modes, highly absorptive or coupled spaces can depart substantially. No target, treatment prescription or measured RT60 is supplied. Record the frequency band and occupancy with your export; measure the actual room.

Method and assumptions documented by Techrider.live

2026-10-24

Frequently asked questions

Can I enter the floor area as absorption?

No. Use equivalent absorption for the same frequency band and occupancy, calculated from reliable material data. The example 1000 m³ and 200 m² sabin gives 0.805 s; it is not a venue recommendation.